Specification
|
|
External dimensions
: mm (W × D × H)
|
180
× 112 × 247
|
Input
voltage
|
AC100V,
50 / 60Hz dual use
|
Power
consumption
|
30
VA or less
|
Ion
balance
(offset voltage)
|
±
10 V or less
Automatic ion balance system
|
Air
flow
|
1.0
- 2.0 m3 / min
stepless manner
|
Ozone
generation amount
|
0.01
PPM or less
Measurement instrument: DASIBI 1003 AH Ozone monitor
(UV
absorption method)
Blower used Measured at 150 mm front side
|
Noise
level
|
57
dB or less
Blower circumference 600 mm, air volume maximum
|
Operable
environment temperature
|
0
to 50 ° C
10 to 85% RH (with no ice condensation)
|
weight
|
About
2.9 kg
|
Air
filter
|
Open
cell polyurethane foam
|
Recommended
distance
(front of blower
~ charged
object)
|
Within
300 mm
|
Static
elimination performance table
Decay time measurement
(electrostatic charging), 1000 V → 100 V (unit: second)
wind speed
|
Measurement
Distance center and left and right 150 mm positions
|
Installation
distance
(m / m)
|
0.3
|
0.6
|
0.9
|
1.2
|
maximum
|
150
|
5
|
7
|
11
|
16
|
Center
|
2
|
5
|
10
|
15
|
150
|
5
|
7
|
11
|
16
|
* Ion balance and decay time
measurement are based on ESD Association ESD STM 3.1-2000.
Measurement electrode: 6 "x 6", metal plate with 20 pF (with charge
monitor)
* Measurement data are reference values and not guaranteed values.