1. Features
High-safety all-exhaust method
The air in the chamber is exhausted to the outside. The chamber is filled with fresh air heated by heater.
Advanced temperature control
The temperature fluctuation ±0.5°C (100°C) and ±1.0°C (200°C) can be obtained thanks to preheating heater.
Adopted uninterruptible power supply
An uninterruptible power supply is adopted to prevent circulating mechanism from stopping by power failure. Additional safety is pursued by using such optional equipment as gas detector.
Uninterruptible power supply
Equipped with explosion vent (safety door)
Controlling gas concentration low can not prevent explosion totally. Some gases may explode even if their concentrations are low. In those cases, the explosion vent will protect you.
Explosive pressure is released from the above when explosion occurs in the chamber.
Contamination control of specimens
The specimen is protected from contaminations caused by substances generated when specimen are heated.
2. Specifications
Model |
SPH-202S |
SPH-302S |
SPH-402S |
System |
All-exhaust method (non-circulating method) |
Power supply |
200V AC 3φ 50/60Hz |
Max. power consumption |
7.7KVA |
10.5KVA |
28.0KVA |
Performance |
Temperature range |
(ambient temp.+40°C) to +200°C |
Temperature fluctuation |
±0.5°C(+100°C)
±1.0°C(+200°C) |
Temperature uniformity |
±1.5°C(+100°C)
±3.0°C(+200°C)
|
±3.0°C(+100°C)
±5.0°C(+200°C) |
±4.0°C(+100°C)
±7.0°C(+200°C) |
Temperature heat-up and pull-down rates* |
Within 60 min. from ambient temp. to +200°C |
Within 70 min. from ambient temp. to +200°C |
Exhaust volume |
About 60m³/h |
About 80m³/h |
About 110m³/h |
Capacity |
216L |
512L |
1000L |
Dimensions |
Inner dimensions |
W600 × H600 × D600mm |
W800 × H800 × D800mm |
W1000 × H1000 × D1000mm |
Outer dimensions |
W1190 × H1910 × D785mm |
W1500 × H2300 × D1065mm |
W1930 × H1800 × D1925mm |
Weight |
270kg |
370kg |
600kg |
Instrumentation |
Setting and indication ranges |
Temperature: 0 to +210°C
Time: 0 to 99 hrs 59 min, 100 to 999 hrs
(1 hour unit for more than 100 hrs) |
Setting and indication resolution |
Temperature:1°C
Time:1 min. |
Program function |
Programmable of 2 steps (2-step fixed) |
* The model name may be changed.