Form
|
DI-12-SL4
|
DI-12-SL02
|
DI-12-SL15
|
Operating range
|
0.030~4.000 N・m
|
1.5~200.0 mN・m
|
0.30~15.00 N・m
|
accuracy
|
±1% (500 or less digit±5digit)
|
±0.5% (200 or less digit±1digit)
|
Display
|
The 4 figures digital display of LCD
|
The measurement direction
|
CW-CCW (right and left)A display will be the display of only an absolute value.
Load of + (the CW direction) and - (the direction of CCW) is carried out to a data output.
|
Measure-ment Mode
|
P-P(peak)
|
The peak load value hold.Destructive torque (the CW direction) -- it loosens and torque (the direction of CCW) is measured.
|
T-R(truck)
|
A display changes with load change.
|
PD
judging mode
|
The judgment of slide torque and the judgment of the yield point are performed.
(Only the CW direction)
|
Detection judging
|
If a slide torque value is detected, you will be told about by green lamp lighting.(at the time of RG mode)
|
Measurement start value setup
|
The value which starts measurement (start of judgment operation) is set up.
( 0.001 N-m unit from 0 N-m)
|
Continuation data output
|
A load torque value is outputted for every fixed time during measurement in RG mode.
By creating a torque wave, loci, such as slide torque, yield point torque, and destructive torque, can be judged.
|
Auto-power-off
|
Automatically power off after 5 minutes left without operation
|
Bit plug form
|
HEX 6.35
|
fai 4
|
6.35sq
|
Data output
|
ASCII format (baud rate 9600). A measurement result is outputted.
|
Outside dimension
|
Detector
|
fai 44×190 Other projection thing
|
fai 20×145
|
fai 55×270
|
Indicator
|
166(W)×142(D)×48(H)
|
Weight
|
Detector
|
About 820g
|
About 80g
|
About 1.5kg
|
Indicator
|
About1kg
|
Accessories
(one piece each)
|
Bit + #1 #2
|
Bit + #0
|
|
An inspection report, a proofreading certificate, a traceability system figure
|