Case:
|
Rugged, water-resistant polycarbonate shell with protective concussion-proof overmold. RFI resistant.
|
Dimensions:
|
3.7 x 2 x 1.1 inches (94 mm x 50.8 mm x 27.9 mm)
|
Weight:
|
3 oz. (85 grams)
|
Measuring Ranges:
|
Gas
|
Symbol
|
Range
|
Increments
|
Carbon Monoxide
|
CO
|
0-1,500
|
1 ppm
|
Hydrogen Sulfide
|
H 2 S
|
0-500 ppm
|
0.1 ppm
|
Oxygen
|
O 2
|
0-30% of volume
|
0.1%
|
Nitrogen Dioxide
|
NO 2
|
0-150 ppm
|
0.1 ppm
|
Sulfur Dioxide
|
SO 2
|
0-150 ppm
|
0.1 ppm
|
Ammonia
|
NH 3
|
0-500 ppm
|
1 ppm
|
Chlorine
|
Cl 2
|
0-100 ppm
|
0.1 ppm
|
Chlorine Dioxide
|
ClO 2
|
0-1 ppm
|
0.01 ppm
|
Phosphine
|
PH 3
|
0-10 ppm
|
0.01 ppm
|
Hydrogen Cyanide
|
HCN
|
0-30 ppm
|
0.1 ppm
|
Hydrogen
|
H 2
|
0-2,000 ppm
|
1 ppm
|
CO/H2 low
|
CO/H2 low
|
0-1,000 ppm
|
1 ppm
|
|
Display:
|
Custom LCD with graphical icons for easy use
Segmented display for direct gas readings
Backlight for low light conditions
"Go/no-go" display mode
Peak reading indication
|
Alarms:
|
User selectable low and high alarms
Ultra-bright LEDs, loud audible alarm (95 dB) and vibrating alarm
|
Battery/Runtime:
|
User replaceable 3V, CR2 Lithium battery
2,600 hour runtime (typical)
|
Event-Logger:
|
Continually on. Logs last 15 alarm events, stamping how long ago the event occurred, the duration of the event, and the peak reading seen during the event.
Event-logger can be viewed on PC or printed directly from the instrument to an infrared printer.
|
Datalogger:
|
One year at one-minute intervals
|
Temperature Range:
|
-40ºC to 60ºC (-40ºF to 140ºF), typical
|
Humidity Range:
|
0-99% RH (non-condensing), typical
|
Approvals:
|
UL and cUL:
- Class I, Div 1, Groups A, B, C, D; T4
- Class I, Zone 0, AEx ia IIC T4
CSA:
- Class I, Div 1, Groups A, B, C, D; T4
- Ex ia IIC T4
ATEX:
-Intrinsic Safety:Safety: EEx ia I/IIC T4
-Equipment group and Category: II 1G; I M2
-EMC: EN50270
Performance: O 2 (EN50104); CO, H 2 S, (EN45544) (pending)
Australia: Ex ia I/IIC T4
IEC: Ex ia IIC T4
Russia: GOST-R Approval (pending)
|