Model
|
High load FGPX-H Series
|
FGPX-250H
|
FGPX-500H
|
Rated capacity (RC)
|
± 2500N
|
± 5000N
|
± 250Kg
|
± 500Kg
|
Display range
|
± 2500N
|
± 5000N
|
± 250.0Kg
|
± 500.0Kg
|
Display resolution
|
1N / 0.1Kg
|
|
Measurement system
|
Normal measurement, plus peak measurement, minus peak measurement
|
Display cycle
|
1 times / sec, 2 times / sec, 3 times / sec., 5 times / sec, 10 times / sec, 20 times / sec.
|
Sampling period
|
1000 times / sec.
|
Accuracy
|
± 0.2% RC and ± 1/2 digit (at 23 ℃)
|
Temperature effect
|
Gain: ± 0.02% / LOAD / ℃, zero: ± 0.02% / RC / ° C.
(zero point drift can be canceled by the tracking function)
|
Indicator
|
LCD signed a four-digit display (character height 12mm)
|
Judgment LED (Hi_NG, OK, Lo_NG) 3 pieces
|
Overload capacity
|
150% RC
|
Comparator function
|
Hi_NG, OK, to determine the Lo_NG, and output in the determination LED and the output signal
|
Communication
|
USB
|
Yes (can communicate with the PC by a dedicated communications software. Connection cable is standard accessory)
|
RS-232C
|
Yes (can communicate with the PC by a dedicated communication command. Connection cable is optional)
|
Digimatic
|
Mitutoyo can be connected to Digimatic printer DP-1VR
|
Analog
|
± 1V (output to ± display range), accuracy ± 50mV, 12bit D / A converter system
|
Output update 1000 times / sec zero can be set, load resistance 10kΩ or more
|
Output
|
Overload
|
PUSH, PULL open collector output (maximum DC30V / 5mA)
|
Comparator
|
HI, OK, LO open collector output (maximum DC30V / 5mA)
|
Input signal
|
ZERO (external zero setting), HOLD (external hold)
|
Power supply
|
AC adapter (DC9V / 200mA) or built-in nickel-metal hydride battery (rechargeable)
|
Charge during the measurement possible battery operating time: about 8 hours after full charge
|
Charging time: up to 16 hours (end automatically when it comes to full charge)
|
Auto power-off function
|
10 minutes (when the AC adapter connection is possible continuous use), invalid settings are also possible
|
Memory function
|
Continuous memory 1,000 / single memory 100 cases / standard memory 50 items
(three types of memory mode switchable)
Yes statistics function (maximum, minimum, peak, average, standard deviation)
|
Operating temperature limit
|
0 ~ 40 ℃ (but without condensation)
|
Operating humidity range
|
35 ~ 85% RH (but no condensation)
|
External dimensions
|
Width 82 × thickness 57 × length 214mm
|
Mass
|
About 900g
|
About 1000g
|
Accessories
|
Measurement adapter (6 types), hanger, AC adapter, carrying case, USB cable, handle
|
Communications software
|
Dedicated communication software free download from (USB compatible) Homepage
|