Model |
SK-1110 |
Cat. No. |
No.8014-03 |
Resolution functions |
0.1°C
Hold: data hold
MAX/MIN Display
AVG: Average temperature
Memory function (150 data)
REL: OFFSET function
Auto power-off setting
(about 30 min.) |
Measuring point (s) |
1 Channel |
Measuring range |
-50 to 1300°C (depends on the probe connected) |
Display range |
-73.3 to 1371°C |
Accuracy (main unit)
(resolution 0.1°C) |
±(0.5% rdg + 1)°C at -50 to 0.0°C
±(0.3% rdg + 1)°C at 0.1 to 1000°C
±(0.5% rdg + 1)°C at 1001 to 1300°C
*Add 1 digit to the above when the resolution is 1°C |
Sampling time |
0.5 sec. |
Sensor |
Type "K" Thermocouple (connector ANSI spec. Yellow in color) |
Power requirements |
"AAA" size manganise (R03) battery x 6 |
Battery life |
Approx 110 hours |
Dimensions (main unit) |
(W) 72 x (H) 151 x (D) 35 mm |
Weight (main unit) |
Approx. 240 g (including batteries) |
Materials (main unit) |
ABS resin Heat resistance: up to 60°C |
Standard accessories |
"AAA" size manganese battery x 6, Vinyl cover |