Vertical System
|
Bandwidth |
40 MHz |
Rise time |
8.8 ns |
Input Channels |
2 |
Bandwidth Limiters |
20 MHz |
Input Impedance |
1 MΩ ± 2% || 17 pF ± 3 pF |
Input Coupling |
AC, DC, GND |
Maximum Input Voltage |
± 400 Vpk |
Channel-Channel Isolation |
≥ 100:1 at 20 MHz |
Vertical Resolution |
8 bits |
Sensitivity |
2 mV/div - 5 V/div |
DC Gain Accuracy |
±3%: 5 mV/div - 5 V/div (fixed gain ranges)
±4%: 2mV/div and variable gain ranges |
Offset Range |
±2 V: 2mV/div - 100 mV/div
±40V: 102 mV/div - 5 V/div |
|
Horizontal System
|
Time/Division Range |
10 ns/div - 50 s/div |
Clock Accuracy |
100 ppm |
Trigger and Interpolator Jitter |
2 ns (pk-pk) |
|
Acquisition System
|
Single-Shot Sample Rate/Ch |
500 MS/s on 1 Ch
250 MS/s on 2 Ch |
Equivalent Sample Rate |
25 GS/s |
Memory |
4 kpts/ch |
|
Acquisition Modes
|
Averaging |
Selectable Number of Sweeps:
4, 16, 32, 64, 128, 256 |
Peak Detect |
10 ns |
Interpolation |
Linear, Sin x/x |
Enhanced Resolution |
na |
Sequence Mode |
na |
|
Triggering System
|
Modes |
Normal, Auto, Single, Stop |
Sources |
Ch 1 - Ch 2, EXT, EXT/5, AC Line |
Coupling Mode |
AC, DC, LF Rej, HF Rej, |
Pre-trigger Delay |
memory/(2 * sample rate) |
Post-trigger Delay |
260 Divisions |
Hold-off by Time or Events |
100 ns - 1.5 s |
Internal Trigger Range |
±6 divisions from center |
Trigger Sensitivity |
1 division: DC - 10 MHz
1.5 divisions: 10 MHz - 40 MHz |
External Trigger Sensitivity |
Ext: 200 mVpp from DC to 10 MHz
300 mVpp from 10 MHz to 40 MHz
Ext/5: 1Vpp from DC to 10 MHz
1.5 mVpp from 10 MHz to 40 MHz |
External Trigger Input Range |
Ext: ±1.2 V, EXT/5: ±6 V |
|
Display
|
Type |
Color 5.7" TFT-LCD |
Resolution |
QVGA; 320 x 234 pixels |
Grid Styles |
YT (12 horizontal divisions), XY |
|
Trigger Types
|
Optional Advanced Triggers |
na |
Optional Serial Data Triggers |
na |
|
Internal Storage
|
Waveform Storage |
20 waveforms and 2 reference waveforms |
Setup Storage |
20 setups |
|
Math
|
Number of Math Traces |
1 |
Standard Math Functions |
Add, Subtract, Multiply, Divide, FFT |
Optional Math Functions |
na |
|
Measurements
|
Number of Measurements Displayed |
5 |
Measurement Parameters |
Amplitude, Average, Base, Burst Width, Cyclical RMS, +Duty Cycle, -Duty Cycle, Fall Time, Frequency, Max, Mean, Min, Overshoot, Peak-Peak, Period, Phase, Rise Time, RMS, Top, +Width, -Width, First Rising-Rising, First Rising-Falling, First Falling-Rising, First Falling-Falling, Last Rising-Rising, Last Rising-Falling, Last Falling-Rising, Last Falling-Falling |
|
Probes
|
Probes |
Qty. (2) ÷10/1 Passive Probes |
Scale Factors |
Manual: ÷1, ÷10, ÷100, ÷1000 |
Calibration Output |
1 kHz square wave, 3Vp-p (typical), output to probe hook |
|
Interface
|
GPIB Port (optional) |
na |
USB (Device) |
1 |
Ethernet Port |
na |
USB (Host) |
1 |
Serial Port |
1 |
|
Power Requirements
|
Voltage |
100 - 240 VAC, 45 Hz to 440 Hz |
Max. Power Consumption |
50 VA |
|
Environmental and Safety
|
Temperature (Operating) |
10 °C to 40 °C |
Temperature (Non-Operating) |
-20 °C to 60 °C |
Humidity (Operating) |
85% RH, 40 °C |
Humidity (Non-Operating) |
85% RH, 65 °C |
Altitude (Operating) |
3000 m |
Altitude (Non-Operating) |
15,266 m |
|
Physical Dimensions
|
Dimensions (HWD) |
154 mm x 305 mm x 133 mm
(6" x 12" x 5.25") |
Weight |
2.3 kg (5 lbs) |
|
Warranty and Service
|
Warranty and Service |
3-year warranty; calibration recommended annually. Optional service programs include extended warranty and calibration services. |