Máy ghi nhận dữ liệu liên tục 5mV đến 20V Hioki MR8740 Mã đặt hàng: 2708

Máy ghi nhận dữ liệu liên tục 5mV đến 20V Hioki MR8740 (Mã đặt hàng: 2708)

Xem tất cả 209 sản phẩm của thương hiệu Hioki

Ứng dụng: Ứng dụng nhiều trong công nghiệp

Thông tin tồn kho:
Liên hệ
Mã sản phẩm MR8740
Thương hiệu: Hioki
Đơn vị tính: Cái
Quy cách đóng gói: Đang cập nhật
Trọng lượng tạm tính: 1Kg

The MR8740 and MR8741 are rack-mountable data acquisition systems that deliver high-speed, multi-channel measurements over maximum of 32+22 channels. The MR8990 DVM unit is a 2-channel input unit for the MR8740/MR8741 for measuring minute fluctuations in output from sensors in automobiles and other equipment and voltage fluctuations in devices such as batteries at high levels of precision and resolution.

 

■ Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

  MR8740 MR8741
Number of channels [Block I: 16 analog units]
From 32 ch analog + 8 ch standard logic inputs
[Block I: 13 analog units + 3 logic units]
26 ch analog + 56 ch logic (8 ch standard logic + 48 ch logic unit)

[Block II: 11 analog units]
From 22 ch analog + 8 ch standard logic
[Block II: 8 analog units + 3 logic units]
16 ch analog + 56 ch logic (8 ch standard logic + 48 ch logic unit)
*Instrument consists of two blocks, Block I and Block II.
*Block I and Block II start measurement simultaneously by means of trigger synchronization (internal setting)
[8 analog units]
From 16 ch analog + 16 ch standard logic
[5 analog units + 3 logic units]
10 ch analog + 64 ch logic (16 standard logic + 48 logic unit)
  Analog unit channels are isolated from each other and from chassis. Logic unit channels and standard logic terminal channels share a common GND with chassis.
Measurement ranges (20 div full scale) 5 mV to 20 V/div, 12 ranges, resolution : 1/100 of range (when using 8966)
5 mV to 50 V/div, 5 ranges, resolution : 1/50,000 of range (when using MR8990)
Max. allowable input 400 V DC (when using 8966; upper limit voltage that can be applied between input terminals without damage)
Max. rated voltage to earth 300 V AC/DC (input and instrument are isolated; between input channels and chassis; upper limit voltage that can be applied between input channels without damage)
Frequency characteristics DC to 5 MHz (-3 dB, when using 8966)
Time axis (MEMORY operation) 5 µs to 5 min/div; 26 ranges; time axis resolution: 100 points/div; time axis expansion: 3 stages from ×2 to ×10; compression: 13 stages from 1/2 to 1/20,000
Measurement functions Memory (high-speed recording), FFT
Memory capacity 16 MW/ch (fixed), total of 864 MW installed 16 MW/ch (fixed), total of 256 MW installed
Removable storage USB memory stick (USB 2.0)
Display None (1 digital DVI terminal per block, 800 × 600 dots) None (1 digital DVI terminal, 800 × 600 dots)
External interfaces [LAN] 100Base-TX (DHCP and DNS support, FTP server, HTTP server)
[USB] USB 2.0 Series A receptacle × 2 (mouse operation)
Power supply 100 to 240 V AC, 50/60 Hz (250 VA max.) 100 to 240 V AC, 50/60 Hz (120 VA max.)
Dimensions and mass 426 mm (16.77 in) W × 177 mm (6.97 in) H × 505 mm (19.88 in) D, 10.8 kg (381.0 oz) (main unit only) 350 mm (13.78 in) W × 160 mm (6.30 in) H × 320 mm (12.60 in) D, 5.4 kg (190.5 oz) (main unit only)
Accessories Instruction manual × 1, Application disk (Wave viewer Wv, Communication commands table) × 1, Power cord × 1

LabVIEW and MATLAB support

Compatible models LabVIEW MATLAB script
MR8740 Available Available
MR8741 Available Available
0 Khách hàng đã đánh giá về sản phẩm này
0/5
5
0%
4
0%
3
0%
2
0%
1
0%