Model | XO-326IIsA XO-326IIsA-V | XO-326IIsB XO-326IIsB-V | XO-326IIsC XO-326IIsC-V |
Cable Length | 5m | 1m (spiral cable) | 10m |
Gas Detected | Oxygen |
Detection Principle | Galvanic cell |
Sampling Method | Diffusion Type |
Detection Range (Service Range) | 0 to 25.0 vol% (25.1 to 40.0 vol%) |
Indication Accuracy | Within ±0.5vol% |
Display Resolution | 0.1vol% |
Alarm Set Value | 1st stage: 19.5vol% 2nd stage: 18.0vol% |
Response Time | Within 20 seconds |
Alarm Function | Buzzer sounds, Red lamp blicks, LCD display blincks (latching), Vibration (for vibration specifications |
Power Source | 2 x size AA alkaline battery (LR6/ made by PANASONIC) |
Continuous Use | Approx. 15,000 hours |
Explosion-Proof Structure | Ex ia II CT3 X (Japan) |
Protection Class | IP20 or equivalent |
Operation Temperature/Humidity | -10 to +40 °C 30 to 85 %RH (non condensing) |
Dimensions (excluding protrusions) | W66 x H170 x D29 mm | W66 x H120 x D29 mm | W66 x H200 x D29 mm |
Weight | Approx. 340g | Approx. 265g | Approx. 410g |