Voltage DC
|
Maximum voltage
|
1000 V
|
Accuracy
|
±(0.09% + 2)
|
Maximum resolution
|
0.001 V
|
Voltage AC
|
Maximum voltage
|
1000 V
|
Accuracy
|
±(2% + 3)
|
AC bandwidth
|
5 kHz1
|
1. with low pass filter; 3 db @ 800 Hz
|
Maximum resolution
|
0.1 mV
|
|
Current DC
|
Maximum amps
|
400 mA
|
Amps accuracy
|
±(0.2% + 2)
|
Maximum resolution
|
0.01 mA
|
Current AC
|
Maximum amps
|
400 mA
|
Amps accuracy
|
±(1.5% + 2)2
|
2. 1 kHz bandwidth
|
Maximum resolution
|
0.01 mA
|
|
Resistance
|
Maximum resistance
|
50 MΩ
|
Accuracy
|
±(0.9% + 2)
|
Maximum resolution
|
0.1 Ω
|
Capacitance
|
Maximum capacitance
|
9,999 µF
|
Accuracy
|
±(1.2% + 2)
|
Maximum resolution
|
1 nF
|
Frequency
|
Maximum frequency
|
100 kHz
|
Accuracy
|
±(0.1% + 1)
|
Maximum resolution
|
0.01 Hz
|
Temperature Measurement
|
-40.0°C to 537°C
|
-40.0°F to 998°F excluding probe
|
Diode test
|
Range/Resolution
|
6 V / 1 mV
|
Accuracy
|
±(2% + 1)
|
Minimum test current @ 1kΩ/V
|
1 mA
|
Test Voltages
|
50, 100, 250, 500, 1000 V
|
Maximum resistance per test voltage
|
1000 V
|
2 GΩ
|
Maximum resolution per test voltage
|
50 V
|
0.01 MΩ
|
100 V
|
0.01 MΩ
|
250 V
|
0.1 MΩ
|
500 V
|
0.1 MΩ
|
1000 V
|
0.1 MΩ
|
Accuracy per test voltage
|
50 V
|
±(3% + 5)
|
100 V
|
±(3% + 5)
|
250 V
|
±(1.5% + 5)
|
500 V
|
±(1.5% + 5)
|
1000 V
|
±(1.5% + 5) to 600 MΩ, ±(10% + 3) above 600 MΩ
|
Operating temperature
|
–20°C to +55°C
|
Storage temperature
|
-40°C to +60°C
|
Humidity (without condensation)
|
0% - 95% (10°C – 30°C)
|
0% - 75% (30°C – 40°C)
|
0% - 40% (40°C – 55°C)
|
Operating altitude
|
2000 m
|
Size
|
203 x 100 x 50 mm (with holster)
|
Weight
|
624 g
|