Rated output voltage |
250 V DC |
500 V DC |
1000 V DC |
Effective maximum indicated value |
100 MΩ |
100 MΩ |
4000 MΩ |
Accuracy 1st effective measuring range |
±5 % of indicated value
0.05 to 50 MΩ |
±5 % of indicated value
0.05 to 50 MΩ |
±5 % of indicated value
2 to 1000 MΩ |
Lower limit resistance |
0.25 MΩ |
0.5 MΩ |
1 MΩ |
|
(Measurement resistance value to maintain testing voltage) |
Overload protection |
1200 V AC (10 sec.) |
Low resistance |
3 Ω (at 200 mA testing current), ±0.09 Ω accuracy,
30 Ω (at 20 mA testing current), ±0.9 Ω accuracy,
Open-circuit voltage: 4.1 to 6.9 V |
AC voltage measurement |
0 to 600 V (50/60 Hz), ±5 % of maximum scale value accuracy,
100 kΩ or more input resistance |
Other functions |
Bright LED luminous scale, Drop proof (on concrete, 1 m/1 time), Battery check, Live circuit check, Auto discharge |
Power supply |
LR6 (AA) alkaline batteries ×4, Continuous use: 20 hours (at 500 V range, no load) |
Dimensions and mass |
159 mm (6.26 in)W × 177 mm (6.97 in)H × 53 mm (2.09 in)D, 610 g (21.5 oz), (including battery, excluding test lead) |
Accessories |
Test lead L9787 ×1, Instruction manual ×1, Shoulder strap ×1, LR6 (AA) alkaline batteries ×4 |