3256-50
|
3257-50
|
DC Voltage
|
420.0 mV to 1000 V, 5 ranges, Basic accuracy: ±0.5 % rdg. ±2 dgt.
|
AC Voltage /50 to 500 Hz
|
420.0 mV to 1000 V, 5 ranges, Basic accuracy: ±1.2 % rdg. ±3 dgt., (Average rectified)
|
420.0 mV to 1000 V, 5 ranges, Basic accuracy: ±1.2 % rdg. ±3 dgt., (True RMS, crest factor 3)
|
Resistance
|
420.0 Ω to 42.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±2 dgt.
|
DC Current
|
42.00 μA to 420.0 mA, 10 A, 6 ranges, Basic accuracy: ±1.5 % rdg. ±4 dgt.
|
AC Current /50 to 500 Hz
|
42.00 μA to 420.0 mA, 10 A, 6 ranges, Basic accuracy: ±2.5 % rdg. ±5 dgt., (Average rectified)
|
42.00 μA to 420.0 mA, 10 A, 6 ranges, Basic accuracy: ±2.5 % rdg. ±5 dgt., (True RMS, crest factor 3)
|
Hz (Frequency)
|
199.99 Hz to 500.0 kHz, 5 ranges, Basic accuracy: ±0.02 % rdg. ±1 dgt., Input level: 0.8 V to 1000 V, 4 levels, Frequencies of less than 0.50 Hz cannot be measured
|
Duty ratio measure
|
Not available
|
5 to 95 % , Frequency range: 10 Hz to 10 kHz, Basic accuracy: ±1.0 % rdg. ±15 dgt.
|
Voltage Detection
|
Bring the top close to the power line, when the voltage is outside of the detection range, buzzer and the display blinks
|
Not available
|
Continuity buzzer
|
Threshold 50 Ω ± 40 Ω, Open terminal voltage: 3.4 V or less
|
Diode check
|
Open terminal voltage: 3.4 V or less, Testing current: 700 μA
|
Other function
|
Relative value, Memory, Auto power save, Auto hold, Recoding (Max./ Min. / Ave.)
|
Display
|
Digital/ LCD, max. 4200 digits (19999 digits at frequency measure)
|
Sample rate
|
2.5 times/s (except Frequency), 5 times/s (Frequency, over 5 Hz), 25 times/s (Update of bar graph)
|
Power supply
|
Manganese battery (R03) ×2, Continuous use: 100 hours
|
Dimensions and mass
|
76W (2.99in) × 167H (6.57in) × 33D (1.30in) mm, 260 g (9.2 oz)
|
Supplied accessories
|
TEST LEAD×1, Instruction Manual×1, Manganese batteries(R03)×2 (for trial purposes only), CARRYING CASE 9378×1
|