Buồng sốc nhiệt TCC-150W, Espec Mã đặt hàng: 6646

Buồng sốc nhiệt TCC-150W, Espec (Mã đặt hàng: 6646)

Thông tin tồn kho:
Liên hệ
Mã sản phẩm TCC-150W
Thương hiệu: Espec
Đơn vị tính: Cái
Quy cách đóng gói: Đang cập nhật
Trọng lượng tạm tính: Đang cập nhật

Thermal Shock Chambers / Rapid-Rate Thermal Cycle Chambers

Model TCC-150W, Espec
 

High temperature rate of change with uniformity and reproducibility

The Rapid-Rate Thermal Cycle Chamber is ideal for test requiring quick changes 15°C/min ramp rate in specimen temperature and 23°C/min ramp rate for air temperature. It covers various applications from JEDEC, IEC standards to screening.

It features new technologies, such as a specimen temperature control function maintaining linear specimen temperature change rates during rapid thermal cycling, and temperature ramp control.

Specifications

Model

Temperature range

Inside / Outside dimensions (mm)

TCC-150W

-70 to +180°C (-94 to +356°F)

W800×H500×D400 / W1000×H1808×D1915

Compatible Test standards

IEC-60749-25 : Semiconductor devices – Temperature cycling

IEC-60068-2-14 Nb : Environmental testing – Change of temperature

IEC-61147-5 : Liquid crystal and solid-state display devices – Environmental, endurance and mechanical test methods

JESD22-A105-B : Solid State Devices, testing quality and reliability – Power and temperature cycling

SAE-J1211 : Automotive components - Recommended environmental practices for electronic equipment design

IPC-9701 : Performance test methods and qualification requirements for surface mount solder attachments

 

Features

Uniformity, reproducibility

Wind simulation allows achieving minimum temperature variations of the specimen, for accurate and quick temperature changes. Specimen temperature ramp rate is 15°C/min, air temperature ramp rate is 23°C/min.

 

Greater temperature ramp control

High precision of the specimen temperature control achieved thanks to a sensor for temperature specimen measurement, and the embedded high-speed controller.

In addition:

  • refrigeration capacities increased at low temperatures,

  • minimization of the difference between test area and specimen temperatures,

  • airflow speed uniformity,

lead to excellent temperature ramp control.

Selection of the temperature control mode

Two temperature control modes are available:

  • A specimen temperature control mode meeting ramp rate conditions of JEDEC standard (15°C/min.)

  • An air temperature control mode for temperature cycle tests.


    Free access

Cable ports are equipped on both left and right side, to ease specimen access and wiring.

 

Description: Graph: Specimen temperature ramp control (Example)Specimen temperature ramp control (Example)

  • Test conditions

High temp. soak

:

+130°C

Low temp. soak

:

-45°C

Ramp rate

:

15°C/min.

   Control point

:

Front center specimen on the lower level

       Specimen

:

Printed Circuit Board, 145 × 130 mm, 90 pcs.

  • Measurement method

45 specimens placed in two rows on two levels in the specimen basket, with thermocouples attached to the surface of each specimen at the control point.

 

Description: Graph: Temperature change (Example)Temperature change (Example)

  • Test conditions

High temp. soak

:

+125°C

Description: https://www.espec.co.jp/english/products/env-test/tcc150/img/img_tcc150_03.jpg

Low temp. soak

:

-40°C

Ramp rate

:

15°C/min.

Control point

:

Air outlet sensor

        Specimen

:

Printed Circuit Board, 145 × 130 mm, 90 pcs.


  •  

  • Measurement method

 As shown on the right, thermocouples are attached to the specimens at twelve measuring point.

 

 

 

 


TEST STANDARD (TCC-150W COMPATIBILTY)

Test standard

Temperature setting

Temperature
change rate

Soak time

Number
of cycles

High temperature (°C)

Low temperature (°C)

IEC 60749-25
(JESD22-A104-D)

G

+125 (+15, -0)

-40 (+0, -10)

Specimen temperature,
15°C / min. or less

1, 5, 10, 15 min.

Not specified

I

+115 (+15, -0)

-40 (+0, -10)

J

+100 (+15, -0)

0 (+0, -10)

K

+125 (+15, -0)

0 (+0, -10)

L

+110 (+15, -0)

-55 (+0, -10)

N

+80 (+15, -0)

-30 (+0, -10)

O

+125 (+15, -0)

-25 (+0, -10)

IEC 60068-2-14 Nb
(JIS C 60068-2-14 Nb)

+175 ±2
+155 ±2
+125 ±2
+100 ±2
+85 ±2
+70 ±2
+55 ±2
+40 ±2
+30 ±2

-65 ±3
-55 ±3
-40 ±3
-25 ±3
-5 ±3
+5 ±3

1±0.2°C / min.
3±0.6°C / min.
5±1.0°C / min.
(AVG)
Average for up to fi ve minutes

3 hours,
2 hours,
1 hour,
30 min.,
10 min.
3 hours if not specified in product specifi cations

2

IEC-61747-5
(EIAJ ED-2531A)

+100 ±2
+95 ±2
+90 ±2
+85 ±2
+80 ±2
+75 ±2
+70 ±2
+65 ±2
+60 ±2
+55 ±2
+50 ±2
+45 ±2
+40 ±2
+35 ±2
+30 ±2

-50 ±3
-45 ±3
-40 ±3
-35 ±3
-30 ±3
-25 ±3
-20 ±3
-15 ±3
-10 ±3
-5 ±3
-0 ±3

1±0.2°C / min.
3±0.6°C / min.
5±1.0°C / min.
(AVG)
Average for up to fi ve minutes

3 hours,
2 hours,
1 hour,
30 min.,
10 min.
3 hours if not specified in product specifi cations

2

JESD22-A105-B

A

+85 (+10, -0)

-40 (+0, -10)

6.25°C / min.

10 min.

1000

B

+125 (+15, -0)

-40 (+0, -10)

5.5°C / min.

IPC-9701

TC1

100

0

Specimen temperature,
20°C / min. or less

Specimen temperature,
10 min.

200
500
1000
3000
6000

TC2

100

-25

TC3

125

-40

TC4

125

-55

TC5

100

-55

IPC-TM-650 2.6.6

A

+125 (+3, -0)

-65 (+0, -5)

-

30 min.

5

B

+85 (+3, -0)

-55 (+0, -5)

SAE-J1211

+85 to +150

-40

4 to 6°C / min.

Low temperature,
4 hours

-

0 Khách hàng đã đánh giá về sản phẩm này
0/5
5
0%
4
0%
3
0%
2
0%
1
0%