Bộ điều khiển mức Omron 61F-G3-220V Mã đặt hàng: 9392

Bộ điều khiển mức Omron 61F-G3-220V (Mã đặt hàng: 9392)

Xem tất cả 290 sản phẩm của thương hiệu Omron

Ứng dụng: là một thiết bị đọc được các tín hiệu truyền về từ cảm biến đo mực nước.

Thông tin tồn kho:
Liên hệ
Mã sản phẩm 61F-G3-220V
Thương hiệu: Omron
Đơn vị tính: Cái
Quy cách đóng gói: Đang cập nhật
Trọng lượng tạm tính: 1Kg

BỘ ĐIỀU KHIỂN MỨC

MODEL: 61F-G3-220V

THƯƠNG HIỆU: OMRON

Thông số kỹ thuật

 

Items

General-purpose Controller 61F-@ (TDL) (see note 1 and 2)

Hightemperature Controller 61F-@T (see note 1)

Long-distance Controllers 61F-@L 2KM (for 2 km) 61F-@L 4KM (for 4 km) (see note 1)

High-sensitivity Controllers 61F-@H (see note 1)

Low-sensitivity Controller 61F-@D (see note 1)

Two-wire Controller 61F-@R (see note 1)

Controlling materials and operating conditions

For control of ordinary purified water or sewage water

For control of ordinary purified water or sewage water in cases where the ambient temperature is high

For control of ordinary purified water in cases where the distance between sewage pumps and water tanks or between receiver tanks and supply tanks is long or where remote control is required

For control of liquids with high specific resistance such as distilled water

For control of liquids with low specific resistance such as salt water, sewage water, acid chemicals, alkali chemicals

For control of ordinary purified water or sewage water used in combination with Two-wire Electrode Holder (incorporating a resistor of 6.8 kΩ) It is possible to wire with less than one wiring against general 61F’s wiring.

Supply voltage

100, 110, 120, 200, 220 or 240 VAC; 50/60 Hz

Operating voltage range

85% to 110% of rated voltage

InterElectrode voltage

8 VAC

24 VAC

8 VAC

InterElectrode current

Approx. 1 mA AC max.

Power consumption

61F-G@: 3.5 VA max.; G1F-G1@, G1F-G2@, or G1F-I@: 5.5 VA max.; G1F-G3@: 7.5 VA max.; G1F-G4@: 14.5 VA max

InterElectrode operate resistance

0 to approx. 4 kΩ

0 to approx. 5 kΩ

0 to approx. 1.8 kΩ (for 2 km) 0 to approx. 0.7 kΩ (for 4 km)

Approx. 15 kΩ to 70 kΩ (see note 5)

0 to approx. 1.8 kΩ

0 to approx. 1.1 kΩ

InterElectrode release resistance

Approx. 15 k to ∞ Ω

Approx. 15 k to ∞ Ω

4 k to ∞ Ω (for 2 km) 2.5 k to ∞ Ω (for 4 km)

Approx. 300 k to ∞ Ω

Approx. 5 k to ∞ Ω

Approx. 15 k to ∞ Ω

Cable length (see note 3)

1 km max.

600 m max

2 km max. 4 km max.

50 m max.

1 km max.

800 m max.

Control output

2 A, 220 VAC (Inductive load: cosφ = 0.4) 5 A, 220 VAC (Resistive load)

Ambient temperature

Operating: –10 to 55°C (–10 to 70°C for 61F-@T)

Ambient humidity

Operating: 45% to 85% RH

Insulation resistance (see note 4)

100 MΩ min. (at 500 VDC)

Dielectric strength (see note 4)

2000 VAC, 50/60 Hz for 1 min

Life expectancy

Electrical: 500,000 operations min. Mechanical: 5,000,000 operations min.

Weight

61F-G@: Approx. 380 g, G1F-G1@, G1F-G2@, or G1F-I@: Approx. 750 g; G1F-G3@: Approx. 930 g; G1F-G4@: Approx. 1,710 g

 

Note:

1. The @ in the model name represents G, G1, G2, G3, G4, and I.

2. The suffix “TDL” attached to the model name represents models designed for tropical regions (storage humidity of 45% to 90%). For details, refer to Safety Precautions for Floatless Level Controllers

3. The length when using completely-insulated, 600-V, 3-conductor (0.75 mm2) cabtire cables. Usable cable lengths will become shorter as the cable diameter or number of conductors becomes larger. For details, refer to Safety Precautions for Floatless Level Controllers

4. The insulation resistance and dielectric strength indicate values between power terminals and Electrode terminals, between power terminals and contact terminals, and between Electrode terminals and contact terminals.

5. Possible to use with 15 kΩ or less, however, this may cause reset failure.

6. High-sensitivity Controllers use advanced operation. When the power supply voltage is applied, if there are some liquids between the electrodes (ground and operation electrodes), the internal relay will not operate. When the power supply voltage is applied, if there are no liquids between the electrodes (ground and operation electrodes), the internal relay will operate